Rated permanent current Iu: 63 A
Device construction: Built-in device fixed built-in technique
Number of poles: 3
Number of command positions: 1
Colour housing cover: Grey
Diameter openings: 22.5 mm
Rated control supply voltage Us at DC: 24...24 V
Voltage type for actuating: DC
Rated operation power at AC-3, 400 V: 4 kW
Number of command positions: 1
Suitable for emergency stop: yes
Number of selector switches: 0
With thermal protection: yes
Rated permanent current Iu: 32 A
Rated operation power at AC-3, 400 V: 15 kW
Rated control supply voltage Us at DC: 24...24 V
Voltage type for actuating: DC
Rated operation power at AC-3, 400 V: 11 kW
Function: Diode
Voltage type (operating voltage): DC
Operating voltage at DC: 12...250 V
Type of electric plug connection: Screw connection
Mounting method: DIN rail (top hat rail) 35 mm
Number of pins: 14
Rated control supply voltage Us at DC: 24...24 V
Voltage type for actuating: DC
Rated operation power at AC-3, 400 V: 15 kW
Setting range overload protector: 26.5...32 A
Rated operating voltage: 200...690 V
Switch off technique: Magnetic
Rated control supply voltage Us at DC: 100...250 V
Voltage type for actuating: AC/DC
Rated control supply voltage Us at AC 50HZ: 100...250 V
- Copy
- Copy
With thermal protection: yes
Rated permanent current Iu: 16 A
Setting range overload protector: 4...16 A
Type of electric plug connection: Screw connection
Time range: 0.5...120 s
Rated control supply voltage Us at AC 50HZ: 100...240 V
Loudness: 105 dB
Nominal voltage: 24...24 V
Type of current: AC/DC
Number of contacts as normally open contact: 1
Rated operation current Ie at AC-15, 230 V: 10 A
Number of contacts as normally closed contact: 1
With thermal protection: yes
Rated permanent current Iu: 2.5 A
Setting range overload protector: 0.63...2.5 A
Adjustment range undelayed short-circuit release: 150...550 A
Setting range overload protector: 50...50 A
Switch off technique: Magnetic
Meaning of the imprint: None
Imprint ISO symbols: None
Colour: Black
Complete with socket: no
Type of electric plug connection: Screw connection
Rated control supply voltage Us at DC: 12...12 V
Type of electric plug connection: Screw connection
Number of contacts as normally open contact: 3
Number of contacts as normally closed contact: 1
Rated control supply voltage Us at DC: 24...24 V
Voltage type for actuating: DC
Rated operation power at AC-3, 400 V: 22 kW
Adjustment range undelayed short-circuit release: 875...1750 A
Setting range overload protector: 175...175 A
Switch off technique: Magnetic
- Copy
- Copy
Number of contacts as normally open contact: 2
Number of contacts as change-over contact: 0
Number of contacts as normally closed contact: 2