Allen-Bradley - OVER CURRENT RELAY 1-10A 115-230v ac - 809S-C1-10A-230

CopyCopy
Allen-Bradley - OVER CURRENT RELAY 1-10A 115-230v ac
£118.28

/ each

£118.28

1

Delivery

Number of available items for delivery:15

Essential specifications

  • Supply voltage AC 50 Hz - 230...230 V

  • Single-phase under current possible - yes

  • Single-phase over current possible - yes

  • Type of electric plug connection - Screw connection

  • With detachable clamps - no

Packaging

  • 1 each

GTIN

10612598965646

Supplier Ref

809S-C1-10A-230

Manufacturer Ref

809S-C1-10A-230

Commercial Reference

809S-C1-10A-230

Supply voltage AC 50 Hz:

230...230 V

Single-phase under current possible:

yes

Single-phase over current possible:

yes

Type of electric plug connection:

Screw connection

With detachable clamps:

no

Voltage type of supply voltage:

AC

Current measurement range:

1...10 A

Three-phase under current possible:

no

Three-phase over current possible:

no

Single-phase hysteresis possible:

no

Three-phase hysteresis possible:

no

Contains function DC-voltage under current:

yes

Contains function DC-voltage over current:

yes

Function DC-current hysteresis:

no

Min. adjustable off-delay time:

1 s

Max. permitted off-delay time:

6 s

Number of contacts as normally closed contact:

0

Number of contacts as normally open contact:

0

Number of contacts as change-over contact:

1

Width:

22.5 mm

Height:

80 mm

Depth:

99.5 mm

MachineAlert Relay. Current Monitor. 10A. 115/230V AC


  • Voltage monitoring relay
  • Guards against the damaging effects of phase loss, under and overvoltage, phase imbalance, phase reversal, and voltage quality of incoming power line
  • Current monitoring relay
  • Provides under and overcurrent detection
  • Thermistor monitoring relay
  • Protects equipment from overtemperature conditions
  • Power (kW) monitoring relay
  • Monitors for under and over active power as well as power direction
  • Power factor (PF) monitoring relay
  • Monitors for under and over power factor detection
  • Programmable latching or inhibit at set level
  • Adjustable time delay settings
  • Three-phase devices are powered by the measuring circuit
  • LED indication for relay, alarm and power supply
  • Global application with CE and UL approvals