HMS - Anybus Gateway - ASI MSR-MBUS SLV - AB7631-F
/ each
£1,063.00
Delivery
Essential specifications
Supply voltage DC - 24...24 V
Supporting protocol for TCP/IP - yes
Supporting protocol for PROFIBUS - no
Supporting protocol for MODBUS - yes
Voltage type of supply voltage - DC
Packaging
1 each
GTIN
Supplier Ref
AB7631-F
Manufacturer Ref
AB7631-F
Commercial Reference
AB7631-F
Supply voltage DC:
24...24 V
Supporting protocol for TCP/IP:
yes
Supporting protocol for PROFIBUS:
no
Supporting protocol for MODBUS:
yes
Voltage type of supply voltage:
DC
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for EtherNet/IP:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for other bus systems:
no
IO link master:
no
IP-rating:
IP20
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Width:
44 mm
Height:
127 mm
Depth:
114 mm
Anybus X-gateway - AS-Interface Master - ModbusTCP Server
- Fast copying of cyclic I/O data between the two networks (10-15 ms).
- Proven and tested with all PLC manufacturers.
- Powerful Master interface eliminates the need for a PLC controller on the AS-Interface network.
- Supports up to a maximum of 512 bytes of Input and Output data in each direction.
- Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network.
- Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
- Optional control status information added to I/O data for diagnostic purposes.
- Robust stand-alone housing for use in harsh industrial environments.
- Global free technical support and consultancy.
- AS-Interface Master Interface:
- An Anybus X-gateway with an integrated AS-Interface M4 Master interface can be used when there is no existing AS-Interface controlling PLC.
- Complies to AS-Interface 3.0 specification.
- Controls up to 62 AS-Interface slaves.
- Optional Live List of the active status of the connected slaves.
- Supports Combined Transaction Types 1, 2, 3, 4 and 51.
- Up to 248 digital inputs and 186 digital outputs.
- Up to 124 (16-bit) analog values.
- AS-Interface baudrate 167 kbit/s.
- Synchronous I/O (optional).
- On-board configuration button.
- 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration.
- 2x 2-pin 5,08 Phoenix plug connectors.
- Modbus TCP Slave interface:
- Modbus TCP Slave settings can be made either via the built-in web interface, or by importing the provided .EDS file into engineering tool of the controlling PLC.
- Conforms to Modbus TCP v1.0.
- Modbus TCP class 0, class 1 and partially class 2 slave functionality.
- 10/100Mbit operation in full or half-duplex.
- Integrated FTP server provides easy file management using standard FTP clients.
- Web server with dynamic data capability and Server Side Include (SSI) capability.
- Email client with dynamic data capability and Event-triggered email handling
- Per-user security framework.
- Quality of Service (QoS) available.
- DNS Capability.
- TCP/IP settings via DHCP/ARP/Anybus IPconfig (HICP).
- Integrated switch allowing for a daisy-chain topology.
- 2x RJ-45 ports available simultaneously.