HMS - Anybus X-gateway - AB7847

/ each
£1,571.00
Delivery
Essential specifications
Supply voltage DC - 24...24 V
Supporting protocol for TCP/IP - no
Supporting protocol for PROFIBUS - yes
Supporting protocol for MODBUS - no
Voltage type of supply voltage - DC
Packaging
1 each
GTIN
Supplier Ref
AB7847
Manufacturer Ref
AB7847
Commercial Reference
AB7847
Supply voltage DC:
24...24 V
Supporting protocol for TCP/IP:
no
Supporting protocol for PROFIBUS:
yes
Supporting protocol for MODBUS:
no
Voltage type of supply voltage:
DC
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for EtherNet/IP:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for other bus systems:
yes
IO link master:
no
IP-rating:
IP20
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Front installation possible:
yes
Rack-assembly possible:
no
Width:
44 mm
Height:
127 mm
Depth:
114 mm
Anybus X-gateway – Interbus CU Slave - PROFIBUS Slave
- Fast copying of cyclic I/O data between two networks (10-15 ms).
- Proven and tested with all PLC manufacturers.
- Supports up to a maximum of 512 bytes of Input and Output data in each direction.
- Optional control and status information added to the I/O data for diagnostic purposes.
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
- Interbus CU Slave Interface
- Interbus Slave address settings can are automatically detected by the controlling PLC.
- Complete Interbus functionality according to EN 50170
- Max. 20 bytes of process data (512 bytes with PCP) in each direction
- PCP V.2.0. (0, 1, 2, or 4 words)
- Interbus baudrate 500 kbit/s – 2 Mbit/s
- Automatic slave address detection by controlling PLC master
- 1x D-sub 9-pin male and 1x D-sub 9-pin female network connector
- PROFIBUS Slave interface
- PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC.
- Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
- Supports Class 1 & Class 2 services
- Automatic baudrate detection up to 12Mbit/s
- Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 344 bytes total (in+out)
- Acyclic User Parameter data / Diagnostics length - up to 237 bytes
- Supports PROFIBUS features: Sync and Freeze and Watchdog
- PROFIBUS slave settings via on-board switches or vis .GSD file
- 1x D-sub 9-pin female PROFIBUS connector