HMS - Anybus X-gateway IIoT-Profinet IRT Slave - AB7570

/ each
£754.00
Delivery
Essential specifications
Supply voltage DC - 24...24 V
Supporting protocol for TCP/IP - yes
Supporting protocol for PROFIBUS - no
Supporting protocol for MODBUS - no
Voltage type of supply voltage - DC
Packaging
1 each
GTIN
Supplier Ref
AB7570
Manufacturer Ref
AB7570
Commercial Reference
AB7570
Supply voltage DC:
24...24 V
Supporting protocol for TCP/IP:
yes
Supporting protocol for PROFIBUS:
no
Supporting protocol for MODBUS:
no
Voltage type of supply voltage:
DC
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for PROFINET IO:
yes
Supporting protocol for EtherNet/IP:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for other bus systems:
no
IO link master:
no
IP-rating:
IP20
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Front installation possible:
yes
Rack-assembly possible:
no
Width:
44 mm
Height:
127 mm
Depth:
114 mm
Anybus X-gateway IIoT - PROFINET-IRT Device – OPC UA-MQTT
- Supports OPC-UA micro-embedded profile
- Supports Discovery Services
- User name and password authentication
- Supports DataChange Subscription
- MQTT client acting as publisher
- Proven and tested with PLC’s from all leading manufacturers
- Possibility to build web pages to display and control a factory floor
- OPC UA
- Support for micro-embedded profile
- Supports Discovery Services
- Timestamp supported via discovery server
- User name and password authentication
- Supports DataChange Subscription
- Maximum 80 data point tags
- Dual port cut-through switch
- Dual RJ-45 ports available simultaneously
- MQTT
- MQTT client acting as publisher
- MQTT version 3.1.1 supported
- Json data encoding supported
- QoS 0-2 supported
- User name and password authentication
- Maximum 256 data point tags
- Dual port cut-through switch
- Dual RJ-45 ports available simultaneously
- PROFINET IRT Device/Slave interface
- PROFINET IRT Device/Slave settings can be made either via the built-in web interface, or by importing the provided .GSDML file into engineering tool of the controlling PLC.
- Complete PROFINET RT and IRT functionality specification 2.3
- Conformance tested supporting Class A, B and C
- Max 512 bytes of Input and 512 bytes of Output data
- Baud rate 10/100 Mbit/s Isochronous cycle times 0.25 to 4 ms (25 Us increments)
- SNMP-MIBII support
- TCP/IP Configuration via DCP (Discovery and Configuration Protocol)
- LLDP (Linked Layer Discovery Protocol)
- Support for I&M (Identification & Maintenance)
- PROFINET uplink configuration via .GSDML file
- Dual port cut-through switch
- Dual RJ-45 ports available simultaneously
HMS
Explore more products in this series


