HMS - CANOPEN MASTER TO PROFIBUS SLAVE - AB7301

/ each
£823.00
Delivery
Essential specifications
Supply voltage DC - 24...24 V
Supporting protocol for TCP/IP - no
Supporting protocol for PROFIBUS - no
Supporting protocol for MODBUS - no
Voltage type of supply voltage - DC
Packaging
1 each
GTIN
Supplier Ref
AB7301
Manufacturer Ref
AB7301
Commercial Reference
AB7301
Supply voltage DC:
24...24 V
Supporting protocol for TCP/IP:
no
Supporting protocol for PROFIBUS:
no
Supporting protocol for MODBUS:
no
Voltage type of supply voltage:
DC
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for EtherNet/IP:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for other bus systems:
yes
IO link master:
no
IP-rating:
IP20
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Front installation possible:
yes
Rack-assembly possible:
no
Width:
75 mm
Height:
27 mm
Depth:
120 mm
Anybus X-gateway – CANopen Master – PROFIBUS Slave
- Fast copying of cyclic I/O data between a CANopen and PROFIBUS network (5 ms)
- Fulll CANopen Master/Manager functionality, eliminates the need for an PLC controller on the CANopen network
- Connects up to 126 CANopen slave devices
- Proven and tested with all PLC manufacturers
- Easy CANopen configuration via the included Anybus Configuration Manager software. No programming required
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
- CANopen Master/Manager Interface
- CANopen Master/Manager implementation according to the CANopen specification DS301 v4.0.2.
- Connects up to 126 CANopen slaves
- Network Management (NMT) messages, to configure and initialize the network.
- Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
- Up to 510 bytes of cyclic data in each direction (PDO)
- PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
- Synchronization Object (SYNC) is used for synchronizing PDO communication.
- Heartbeat Mechanism to monitor the status of nodes.
- Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
- EMCY (Emergency Object) is used for error reporting.
- LSS master functionality
- Can also function as a CANopen Slave
- PROFIBUS Slave interface
- PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC.
- Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
- Supports Class 1 & Class 2 services
- Automatic baudrate detection up to 12Mbit/s
- Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 344 bytes total (in+out)
- Acyclic User Parameter data / Diagnostics length - up to 237 bytes
- Supports PROFIBUS features: Sync and Freeze and Watchdog
- PROFIBUS slave settings via on-board switches or vis .GSD file
- 1x D-sub 9-pin female PROFIBUS connector
HMS