HMS - DeviceNet Master-Modbus RTU slave - AB7817

/ each
£899.00
Delivery
Essential specifications
Supply voltage DC - 24...24 V
Supporting protocol for TCP/IP - no
Supporting protocol for PROFIBUS - no
Supporting protocol for MODBUS - yes
Voltage type of supply voltage - DC
Packaging
1 each
GTIN
Supplier Ref
AB7817
Manufacturer Ref
AB7817
Commercial Reference
AB7817
Supply voltage DC:
24...24 V
Supporting protocol for TCP/IP:
no
Supporting protocol for PROFIBUS:
no
Supporting protocol for MODBUS:
yes
Voltage type of supply voltage:
DC
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
yes
Supporting protocol for PROFINET IO:
no
Supporting protocol for EtherNet/IP:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for other bus systems:
yes
IO link master:
no
IP-rating:
IP20
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Front installation possible:
yes
Rack-assembly possible:
no
Width:
44 mm
Height:
127 mm
Depth:
114 mm
Anybus X-gateway – DeviceNet Scanner - Modbus RTU Slave
- Fast copying of cyclic I/O data between two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Powerful Scanner interface for DeviceNet eliminates the need for a PLC controller
- Optional control and status information added to the I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
- DeviceNet Scanner/Master features
- An Anybus X-gateway with an integrated DeviceNet Scanner interface can be used when there is no existing DeviceNet controlling PLC.
- DeviceNet CONFORMANCE TESTED™ by ODVA
- DeviceNetNet Specification version: Communications Adapter profile 12
- Supports up to 63 DeviceNet Adapter/Slaves
- Max. 512 bytes of Input and 512 bytes of Output data
- Optional Live List of the active status of the connected adapters
- DeviceNet baudrate 125, 250, 500 kbit/s
- Supports I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
- MacID node address setting via DIP switches
- DeviceNet Scanner/Adapter network configuration via in-built web interface or RSLogix/Studio5000 software
- 1x 5-pin, 5.08 Phoenix plug connector
- Modbus RTU Slave interface
- Modbus RTU network address settings made via on-board configuration switches
- Complete Modbus RTU slave functionality
- Max 512 bytes of Input and 512 bytes of Output data
- Modbus diagnostics support
- Configuration via on-board DIP switches
- Modbus RTU baudrate 12-57,6 kbit/s
- 1x D-sub 9-pin female network connector
HMS
Explore more products in this series


