Merlin Gerin - ACTI9 IC60H 1P 25A D MINIATURE CIRCUIT B - A9F55125

CopyCopy
Merlin Gerin - ACTI9 IC60H 1P 25A D MINIATURE CIRCUIT B
£29.06

/ each

£29.06

1

Delivery

Number of available items for delivery:0

Essential specifications

  • Release characteristic - D

  • Number of poles (total) - 1

  • Number of protected poles - 1

  • Rated current - 25 A

  • Built-in depth - 78.5 mm

Packaging

  • 1 each

GTIN

3606480515231

Supplier Ref

A9F55125

Manufacturer Ref

A9F55125

Commercial Reference

A9F55125

Release characteristic:

D

Number of poles (total):

1

Number of protected poles:

1

Rated current:

25 A

Built-in depth:

78.5 mm

Rated voltage:

240 V

Voltage type:

AC

Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V:

30 kA

Frequency:

50...60 Hz

Current limiting class:

3

Pollution degree:

3

IP-rating:

IP20

Miniature Circuit Breaker. 25A. 1-pole. Type D. Trip 12n ± 20 %


  • With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
  • VisiSafe : for safe operation and maintenance work on circuits.
  • Class-2 insulation : continuous safety for operators and unqualified personnel.
  • VisiTrip : detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.
  • Add-on fully immune earth leakage protection devices : better continuity of service, especially in polluted environments and networks.
  • Nominal current: 1 to 63 A
  • Large choice of breaking capacities up to 100 kA and tripping curves: B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
  • Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
  • Suitable for isolation in accordance with industrial standard IEC 60947
  • Operating voltage: up to 440 V AC, insulation voltage: 500 V
  • Optional add-on earth leakage modules: iC60 Vigi,
  • Optional auxiliaries: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
  • The new reference in final distribution,
  • Absolute safety of circuit protection with VisiSafe,
  • Greater continuity of service with VisiTrip,
  • Simple to choose with meaningful part numbers,
  • Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
  • Environmentally friendly with 100% recyclable & recoverable materials.

Merlin Gerin