Essential specifications

  • Number of channels - 1

  • IP-rating - IP20

  • Type of power supply - Active

  • Rated supply voltage at DC - 19.2...30 V

  • Number of input ranges -60 mV ... +60 mV - 0

Packaging

  • 1 each

GTIN

4046356160353

Supplier Ref

2865340

Manufacturer Ref

2865340

Commercial Reference

2865340

Number of channels:

1

IP-rating:

IP20

Type of power supply:

Active

Rated supply voltage at DC:

19.2...30 V

Number of input ranges -60 mV ... +60 mV:

0

Number of input ranges -100 mV ... +100 mV:

0

Number of input ranges -300 mV ... +300 mV:

0

Number of input ranges -500 mV ... +500 mV:

0

Number of input ranges -1 V ... +1 V:

0

Number of input ranges -2 V ... +2 V:

0

Number of input ranges -2.5 V ... +2.5 V:

0

Number of input ranges -5 V ... +5 V:

0

Number of input ranges -10 V ... +10 V:

0

Number of input ranges -20 V ... +20 V:

0

Number of input ranges 0 mV ... 60 mV:

0

Number of input ranges 0 mV ... 100 mV:

0

Number of input ranges 0 mV ... 200 mV:

0

Number of input ranges 0 mV ... 300 mV:

0

Number of input ranges 0 mV ... 500 mV:

0

Number of input ranges 0 V ... 1 V:

0

Number of input ranges 0 V ... 2 V:

0

Number of input ranges 0 V ... 2.5 V:

0

Number of input ranges 0 V ... 5 V:

0

Number of input ranges 0 V ... 10 V:

0

Number of input ranges 0 V ... 20 V:

0

Number of input ranges 0 V ... 24 V:

0

Number of input ranges 0 V ... 30 V:

0

Number of input ranges 1 V ... 5 V:

0

Number of input ranges 2 V ... 10 V:

0

Number of input ranges +5 V ... -5 V:

0

Number of input ranges +10 V ... -10 V:

0

Number of input ranges 5 V ... 0 V:

0

Number of input ranges 5 V ... 1 V:

0

Number of input ranges 10 V ... 0 V:

0

Number of input ranges 10 V ... 2 V:

0

Number of input ranges 0 mA ... 5 mA:

0

Number of input ranges 0 mA ... 10 mA:

0

Number of input ranges 0 mA ... 20 mA:

0

Number of input ranges 4 mA ... 20 mA:

1

Number of input ranges -5 mA ... +5 mA:

0

Number of input ranges -10 mA ... +10 mA:

0

Number of input ranges -20 mA ... +20 mA:

0

Number of input ranges 20 mA ... 0 mA:

0

Number of input ranges 20 mA ... 4 mA:

0

Number of output ranges -60 mV ... +60 mV:

0

Number of output ranges -100 mV ... +100 mV:

0

Number of output ranges -300 mV ... +300 mV:

0

Number of output ranges -500 mV ... +500 mV:

0

Number of output ranges -1 V ... +1 V:

0

Number of output ranges -2 V ... +2 V:

0

Number of output ranges -2.5 V ... +2.5 V:

0

Number of output ranges -5 V ... +5 V:

0

Number of output ranges -10 V ... +10 V:

0

Number of output ranges -20 V ... +20 V:

0

Number of output ranges 0 mV ... 60 mV:

0

Number of output ranges 0 mV ... 100 mV:

0

Number of output ranges 0 mV ... 200 mV:

0

Number of output ranges 0 mV ... 300 mV:

0

Number of output ranges 0 mV ... 500 mV:

0

Number of output ranges 0 V ... 1 V:

0

Number of output ranges 0 V ... 2 V:

0

Number of output ranges 0 V ... 2.5 V:

0

Number of output ranges 0 V ... 5 V:

0

Number of output ranges 0 V ... 10 V:

0

Number of output ranges 0 V ... 20 V:

0

Number of output ranges 0 V ... 24 V:

0

Number of output ranges 0 V ... 30 V:

0

Number of output ranges 1 V ... 5 V:

0

Number of output ranges 2 V ... 10 V:

0

Number of output ranges +5 V ... -5 V:

0

Number of output ranges +10 V ... -10 V:

0

Number of output ranges 5 V ... 0 V:

0

Number of output ranges 5 V ... 1 V:

0

Number of output ranges 10 V ... 0 V:

0

Number of output ranges 10 V ... 2 V:

0

Number of output ranges 0 mA ... 5 mA:

0

Number of output ranges 0 mA ... 10 mA:

0

Number of output ranges 0 mA ... 20 mA:

0

Number of output ranges 4 mA ... 20 mA:

2

Number of output ranges -5 mA ... +5 mA:

0

Number of output ranges -10 mA ... +10 mA:

0

Number of output ranges -20 mA ... +20 mA:

0

Number of output ranges 20 mA ... 0 mA:

0

Number of output ranges 20 mA ... 4 mA:

0

Inherently safe according to EN 60947-5-6 NAMUR:

yes

Galvanic separation between inputs:

no

Galvanic separation between input and output:

yes

Galvanic separation between output to output:

no

Galvanic separation between supply voltage and all other current circuits:

yes

Height:

112.5 mm

Width:

12.5 mm

Depth:

114.5 mm

Power consumption:

1.8 W

Load:

1000...1000 Ohm

Operation temperature:

-20...60 °C

Temperature drift:

0.004 %/K

Device construction:

Built-in device

Type of electric plug connection:

Screw connection

Mounting method:

Snap mounting support rail

Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw connection


  • Power supply and error indication possible via DIN rail connector
  • Up to SIL 2 according to EN 61508
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Line fault detection (LFD), can be activated/deactivated, error indicated by red flashing LED with disabling of transistor output
  • Transistor signal output (passive); up to 5 kHz
  • Direction of operation can be selected (operating or closed circuit current behavior)
  • LED indicators for supply voltage, switching state, and malfunction according to NAMUR NE 44
  • 3-way electrical isolation
  • 2-channel
  • Input for NAMUR proximity sensors (EN 60947-5-6), floating contacts or contacts with resistance circuit, [Ex ia] IIC