homepage

Log in or sign up today.LoginSign up

Phoenix Contact - MINI MCR-SL-R-UI - 2864095

CopyCopy
Phoenix Contact - MINI MCR-SL-R-UI
£256.76

/ each

£256.76

1

Delivery

Number of available items for delivery:0

Essential specifications

  • Number of channels - 1

  • IP-rating - IP20

  • Type of power supply - Active

  • Rated supply voltage at DC - 19.2...30 V

  • Number of input ranges -60 mV ... +60 mV - 0

Packaging

  • 1 each

GTIN

4046356046442

Supplier Ref

2864095

Manufacturer Ref

2864095

Commercial Reference

2864095

Number of channels:

1

IP-rating:

IP20

Type of power supply:

Active

Rated supply voltage at DC:

19.2...30 V

Number of input ranges -60 mV ... +60 mV:

0

Number of input ranges -100 mV ... +100 mV:

0

Number of input ranges -300 mV ... +300 mV:

0

Number of input ranges -500 mV ... +500 mV:

0

Number of input ranges -1 V ... +1 V:

0

Number of input ranges -2 V ... +2 V:

0

Number of input ranges -2.5 V ... +2.5 V:

0

Number of input ranges -5 V ... +5 V:

0

Number of input ranges -10 V ... +10 V:

0

Number of input ranges -20 V ... +20 V:

0

Number of input ranges 0 mV ... 60 mV:

0

Number of input ranges 0 mV ... 100 mV:

0

Number of input ranges 0 mV ... 200 mV:

0

Number of input ranges 0 mV ... 300 mV:

0

Number of input ranges 0 mV ... 500 mV:

0

Number of input ranges 0 V ... 1 V:

0

Number of input ranges 0 V ... 2 V:

0

Number of input ranges 0 V ... 2.5 V:

0

Number of input ranges 0 V ... 5 V:

0

Number of input ranges 0 V ... 10 V:

0

Number of input ranges 0 V ... 20 V:

0

Number of input ranges 0 V ... 24 V:

0

Number of input ranges 0 V ... 30 V:

0

Number of input ranges 1 V ... 5 V:

0

Number of input ranges 2 V ... 10 V:

0

Number of input ranges +5 V ... -5 V:

0

Number of input ranges +10 V ... -10 V:

0

Number of input ranges 5 V ... 0 V:

0

Number of input ranges 5 V ... 1 V:

0

Number of input ranges 10 V ... 0 V:

0

Number of input ranges 10 V ... 2 V:

0

Number of input ranges 0 mA ... 5 mA:

0

Number of input ranges 0 mA ... 10 mA:

0

Number of input ranges 0 mA ... 20 mA:

0

Number of input ranges 4 mA ... 20 mA:

0

Number of input ranges -5 mA ... +5 mA:

0

Number of input ranges -10 mA ... +10 mA:

0

Number of input ranges -20 mA ... +20 mA:

0

Number of input ranges 20 mA ... 0 mA:

0

Number of input ranges 20 mA ... 4 mA:

0

Number of output ranges -60 mV ... +60 mV:

0

Number of output ranges -100 mV ... +100 mV:

0

Number of output ranges -300 mV ... +300 mV:

0

Number of output ranges -500 mV ... +500 mV:

0

Number of output ranges -1 V ... +1 V:

0

Number of output ranges -2 V ... +2 V:

0

Number of output ranges -2.5 V ... +2.5 V:

0

Number of output ranges -5 V ... +5 V:

0

Number of output ranges -10 V ... +10 V:

0

Number of output ranges -20 V ... +20 V:

0

Number of output ranges 0 mV ... 60 mV:

0

Number of output ranges 0 mV ... 100 mV:

0

Number of output ranges 0 mV ... 200 mV:

0

Number of output ranges 0 mV ... 300 mV:

0

Number of output ranges 0 mV ... 500 mV:

0

Number of output ranges 0 V ... 1 V:

0

Number of output ranges 0 V ... 2 V:

0

Number of output ranges 0 V ... 2.5 V:

0

Number of output ranges 0 V ... 5 V:

1

Number of output ranges 0 V ... 10 V:

1

Number of output ranges 0 V ... 20 V:

0

Number of output ranges 0 V ... 24 V:

0

Number of output ranges 0 V ... 30 V:

0

Number of output ranges 1 V ... 5 V:

1

Number of output ranges 2 V ... 10 V:

0

Number of output ranges +5 V ... -5 V:

0

Number of output ranges +10 V ... -10 V:

0

Number of output ranges 5 V ... 0 V:

0

Number of output ranges 5 V ... 1 V:

0

Number of output ranges 10 V ... 0 V:

1

Number of output ranges 10 V ... 2 V:

0

Number of output ranges 0 mA ... 5 mA:

0

Number of output ranges 0 mA ... 10 mA:

0

Number of output ranges 0 mA ... 20 mA:

1

Number of output ranges 4 mA ... 20 mA:

1

Number of output ranges -5 mA ... +5 mA:

0

Number of output ranges -10 mA ... +10 mA:

0

Number of output ranges -20 mA ... +20 mA:

0

Number of output ranges 20 mA ... 0 mA:

1

Number of output ranges 20 mA ... 4 mA:

1

Malfunction message output:

no

Inherently safe according to EN 60947-5-6 NAMUR:

no

Galvanic separation between inputs:

no

Galvanic separation between input and output:

yes

Galvanic separation between output to output:

no

Galvanic separation between supply voltage and all other current circuits:

yes

Height:

93.1 mm

Width:

6.2 mm

Depth:

102.5 mm

Power consumption:

0.5 W

Load:

500...500 Ohm

Operation temperature:

-20...65 °C

Temperature drift:

0.02 %/K

Device construction:

Built-in device

Type of electric plug connection:

Screw connection

Mounting method:

Snap mounting support rail

MCR potiposition transducer for conversion of potentiometer positions into a standard analog signal, 0 Ω input... 100 Ω to 0 kΩ ... 100 kΩ


  • The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6.2 mm and converts potentiometer positions as a percentage to an analog standard signal. If the potentiometer range cannot be utilized to the full, an externally accessible slide switch is used to set the upper and lower potiposition end values. The output signal between 0 and 100% is based on this fixed end value.
  • The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:
  • - Output signal,
  • - Automatic potentiometer detection,
  • - Open circuit detection slider and
  • - Fault evaluation type.
  • Power (19.2 V DC to 30 V DC) can be supplied through connection terminals on the modules or in conjunction with the DIN rail connector.
  • Your advantages
  • Power supply possible via the foot element (TBUS)
  • Automatic potentiometer detection without manual adjustment
  • Error indication via diagnostic LED and analog signal
  • For 100 Ω to 100 kΩ potentiometers
  • potentiometer signals to create standard signals
  • Configurable measuring range and output signals
  • Highly-compact potentiometer transducer for electrical isolation, conversion, amplification, and filtering of
  • Input and output signals can be configured via DIP switches
  • 3-way isolation
  • A potentiometer sub-range can be linearized via the "teach-in" switch on the device