homepage

Log in or sign up today.LoginSign up

Pilz - PNOZ E6VP - 774193

CopyCopy
£543.08

/ each

£543.08

1

Delivery

Number of available items for delivery:0

Essential specifications

  • Model - Basic device

  • Voltage type of supply voltage - DC

  • Supply voltage DC - 24...24 V

  • Evaluation inputs - 2-channel

  • Rail mounting possible - yes

Packaging

  • 1 each

GTIN

4046548011777

Supplier Ref

774193

Manufacturer Ref

774193

Commercial Reference

774193

Model:

Basic device

Voltage type of supply voltage:

DC

Supply voltage DC:

24...24 V

Evaluation inputs:

2-channel

Rail mounting possible:

yes

With detachable clamps:

yes

Type of electric plug connection:

Screw connection

Suitable for monitoring of position switches:

no

Suitable for monitoring of emergency-stop circuits:

yes

Suitable for monitoring of valves:

no

Suitable for monitoring of optoelectronic protection equipment:

yes

Suitable for monitoring of tactile sensors:

yes

Suitable for monitoring of magnetic switches:

no

Suitable for monitoring of proximity switches:

no

With muting function:

no

Number of outputs, safety related, instantaneous, with contact:

1

Number of outputs, safety related, delayed, with contact:

1

Number of outputs, safety related, instantaneous, semiconductors:

0

Number of outputs, safety related, delayed, semiconductors:

0

Number of outputs, signalling function, instantaneous, with contact:

0

Number of outputs, signalling function, delayed, with contact:

0

Number of outputs, signalling function, instantaneous, semiconductors:

0

Number of outputs, signalling function, delayed, semiconductors:

0

Performance level acc. to EN ISO 13849-1:

Level e

With approval for BG BIA:

no

With approval according to UL:

yes

Width:

45 mm

Height:

94 mm

Depth:

121 mm

PNOZ e6vp 24VDC 4n/o 1so 1so t. Safety gate monitor, Instantaneous E-STOP monitoring, Limit switch, Delayed E-STOP monitoring, Light beam device mon. Type 4, Light beam device mon. Type 2 w/o t/p, Light beam device mon. Type 2 with t/p, Safe delay-on de-energ. timer. Single-channel, Automatic reset, Dual-channel, Detection of shorts across contacts, Start-up testing, Monitored manual reset, without detection of shorts across contacts, Self test, Prog. delay-on de-energisation, with AND input, With OR input