Input voltage at AC 50 Hz - 0...0 V
Input voltage at DC - 24...24 V
Type of input voltage - DC
Number of slots - 0
Fieldbus connection via separate bus coupler possible - no
Packaging
1 each
GTIN
Supplier Ref
1334920000
Manufacturer Ref
1334920000
Commercial Reference
1334920000
Input voltage at AC 50 Hz:
0...0 V
Input voltage at DC:
24...24 V
Type of input voltage:
DC
Number of slots:
0
Fieldbus connection via separate bus coupler possible:
no
With integrated power supply:
yes
Input voltage at AC 60 Hz:
0...0 V
Max. input current AC 50 Hz:
0 A
Max. input current AC 60 Hz:
0 A
Max. input current DC:
10 A
Output voltage at AC 50 Hz:
0...0 V
Output voltage at AC 60 Hz:
0...0 V
Output voltage at DC:
24...24 V
Type of output voltage:
DC
Max. output current AC 50 Hz:
0 A
Max. output current AC 60 Hz:
0 A
Max. output current DC:
10 A
Number of HW-interfaces industrial Ethernet:
2
Number of HW-interfaces PROFINET:
0
Number of HW-interfaces RS-232:
0
Number of HW-interfaces RS-422:
0
Number of HW-interfaces RS-485:
0
Number of HW-interfaces serial TTY:
0
Number of HW-interfaces USB:
1
Number of HW-interfaces parallel:
0
Number of HW-interfaces Wireless:
0
Number of HW-interfaces other:
0
With optical interface:
no
Supporting protocol for TCP/IP:
yes
Supporting protocol for PROFIBUS:
no
Supporting protocol for CAN:
no
Supporting protocol for INTERBUS:
no
Supporting protocol for ASI:
no
Supporting protocol for KNX:
no
Supporting protocol for MODBUS:
no
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for SUCONET:
no
Supporting protocol for LON:
no
Supporting protocol for SERCOS:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for PROFINET CBA:
no
Supporting protocol for Foundation Fieldbus:
no
Supporting protocol for EtherNet/IP:
yes
Supporting protocol for AS-Interface Safety at Work:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for INTERBUS-Safety:
no
Supporting protocol for PROFIsafe:
no
Supporting protocol for SafetyBUS p:
no
Supporting protocol for other bus systems:
no
Radiostandard Bluetooth:
no
Radiostandard WLAN 802.11:
no
Radio standard GPRS:
no
Radio standard GSM:
no
Radio standard UMTS:
no
IO link master:
no
System accessory:
yes
IP-rating:
IP20
Digital I/O plug-in modules possible:
no
Analogue I/O plug-in modules possible:
no
Communication plug-in modules possible:
no
Function and technology plug-in modules possible:
no
Central plug-in modules possible:
no
Other plug-in modules possible:
no
Type of electric plug connection:
Plug-in connection
With potential separation:
no
Bus coupler for modular station connection available:
yes
Rail mounting possible:
yes
Wall mounting/direct mounting:
no
Front installation possible:
no
Rack-assembly possible:
no
Suitable for safety functions:
no
SIL according to IEC 61508:
None
Performance level acc. to EN ISO 13849-1:
Level a
Appendant operation agent (Ex ia):
no
Appendant operation agent (Ex ib):
no
Explosion safety category for gas:
None
Explosion safety category for dust:
None
Width:
52 mm
Height:
120 mm
Depth:
76 mm